This desktop software simulates a Grid-Tie Inverter and is second version of a similar desktop app which I wrote in C language. I wrote this version from scratch in Python and added a few more features and improved some features that exist in first version.
The Grid-Tie Inverter Simulation is a desktop software to simulate a grid-connected inverter under various configurations, including single-phase or three-phase topologies, multilevel inverter designs, DC source types (Fixed, PV Panel, Battery, Fuel Cell, Hybrid), control strategies, maximum power point tracking (MPPT) algorithms, and grid conditions.
- Inverter Simulation Core (
InverterSimulation.py): Orchestrates the simulation by integrating DC sources, phase topologies, multilevel inverters, control algorithms, MPPT, phase-locked loop (PLL), and islanding detection to generate realistic voltage and current waveforms. - DC Sources (
DCSource.py): Models DC inputs with distinct physical characteristics for different source types, providing voltage to the inverter. - Phase Topologies (
Wechselrichtertopologie.py): Generates single-phase or three-phase waveforms based on inverter configuration. - Multilevel Inverters (
MehrstufigeWechselrichter.py): Produces multilevel output voltages for advanced inverter designs like Neutral Point Clamped (NPC) or Modular Multilevel Converter (MMC). - Control Strategies (
InverterSimulation.py,AdaptiveKontrollstrategien.py): Implements control methods (PI, PR, Sliding Mode, MPC, Q-learning) to regulate inverter output for grid synchronization and performance. - MPPT Algorithms (
MaximaleLeistungspunktverfolgung.py,Welligkeitskorrelationssteuerung.py): Optimizes power extraction from PV or hybrid sources using algorithms like Perturb & Observe or Ripple Correlation Control. - Grid Simulation (
GridSimulation.py): Simulates grid voltage with configurable faults (sag, swell, harmonics, frequency shift) and weak grid conditions. - Islanding Detection (
IslandingDetection.py): Detects grid disconnection using passive and active methods. - Phase-Locked Loop (
Phasenregelkreis.py): Synchronizes inverter output with the grid phase. - Time-Domain Simulation (
Zeitbereichssimulation.py): Analyzes transient behavior with configurable time steps. - Frequency-Domain Analysis (
FrequenzbereichsUndKleinsignalanalyse.py): Performs small-signal analysis to evaluate system stability via Bode plots.
The simulation operates in a time-stepped manner, updating system states and generating waveforms based on user inputs and dynamic conditions.
- Initialization: The
MainWindowclass creates anInverterSimulationobject with default parameters: DC voltage = 400V, frequency = 50Hz, modulation index = 0.8, time window = 0.04s, time step = 0.001s. It initializes DC source, phase topology, PLL, and islanding detector. - Parameter Updates: User inputs from the control panel (e.g., DC source type, topology, control method) are sent via signals (
parameters_changed,topology_changed, etc.) toInverterSimulation.update_simulation_parameters, which updates:- Frequency, modulation index, and DC voltage (if Fixed source).
- MPPT state (irradiance, temperature, SOC, load current).
- PLL and islanding detector parameters.
- Waveform Generation (
InverterSimulation.generate_waveforms):- Islanding Check: Calls
IslandingDetector.detectwith grid voltage (fromGridSimulation.pyor default 230V RMS sine wave). If islanding is detected, returns zero voltage/current arrays. - DC Voltage Update: Calls
DCSource.updatewith MPPT state parameters (irradiance = 1000 W/m², temperature = 25°C, SOC = 0.8, load current = 10A by default) to compute the DC voltage. - MPPT Application: If enabled, calls
MPPTAlgorithm.updateto adjust DC voltage for maximum power. - Waveform Generation:
- Uses
SinglePhaseTopologyorThreePhaseTopologyto generate base sinusoidal waveforms (230V RMS, scaled by modulation index). - If a multilevel inverter is selected, calls
MultilevelInverter.generate_waveformswith the chosen PWM technique (Multicarrier or Space Vector).
- Uses
- Grid Synchronization: Calls
PLL.updatewith a grid voltage sample to compute phase angle for waveform alignment. - Control Application: Calls
InverterSimulation.apply_controlto regulate voltage and current using the selected control method (PI, PR, Sliding Mode, MPC). - Design Adjustment: Applies
TransformerlessDesignorTransformerBasedDesignto modify waveforms (e.g., DC offset or efficiency loss). - Time Advance: Increments current time by time_window / 2 (0.02s) for continuous simulation.
- Islanding Check: Calls
- Periodic Updates: A QTimer in
Main.pytriggersupdate_waveformsevery 100ms, generating new waveforms and updating plots.
- Parameters:
- Base time step: 0.01–10ms (converted to seconds).
- Variation factor: 0–1 (for sinusoidal time step variation).
- Duration: 0.1–10s.
- Adaptive stepping: Optional, adjusts time step based on voltage gradients.
- Time Steps: Generates
num_steps = duration / base_time_stepsteps, with variation:time_steps = base_time_step * (1 + variation_factor * sin(0 to 2π)). - Adaptive Stepping: If enabled, computes voltage gradient (
|V(t) - V(t-1)| / dt). If gradient > 1000 V/s, reduces time step by 0.5x; if < 100 V/s, increases by 1.5x, clipped to [0.1 * base_time_step, 2 * base_time_step]. - Simulation:
- Iterates
num_stepstimes, overridingInverterSimulation.time_stepandtime_window(set to 10 * time_step). - Calls
generate_waveformsto produce voltage/current for each phase. - Stores single-point data (first sample of each waveform) for efficiency.
- Updates progress bar:
progress = (i + 1) / num_steps * 100.
- Iterates
- Output: Stores time, voltages, and currents as NumPy arrays for plotting and CSV export.
- Parameters:
- Start frequency: 0.1–1000Hz.
- End frequency: 10–100kHz.
- Analysis type: Open-Loop or Closed-Loop.
- Perturbation amplitude: 0.1–10% (scaled to 0.001–0.1).
- Frequency Points: Generates 100 logarithmically spaced frequencies using
np.logspace(log10(f_start), log10(f_end), 100). - Model: Simplified PI controller + LC filter:
- PI:
G_pi = Kp + Ki / s, with Kp = 0.1, Ki = 10. - LC Filter:
G_filter = 1 / (L * C * s^2 + 1), with L = 0.001H, C = 100e-6F. - Transfer Function:
- Open-Loop:
G = G_pi * G_filter. - Closed-Loop:
G = (G_pi * G_filter) / (1 + G_pi * G_filter).
- Open-Loop:
- Applies perturbation:
G *= (1 + perturbation).
- PI:
- Calculation:
- For each frequency f, computes
s = 2j * π * f. - Gain:
20 * log10(|G|). - Phase:
angle(G, deg=True).
- For each frequency f, computes
- Output: Stores frequencies, gains, and phases for Bode plots and CSV export.
- Q-Learning Controller:
- State: Tracking error (V_grid - max(|V_inverter|)) discretized into 10 bins from -50V to 50V.
- Action: Modulation index adjustment in 5 steps: [-0.1, -0.05, 0, 0.05, 0.1].
- Parameters: Learning rate (α = 0.01–1), discount factor (γ = 0–1), exploration rate (ε = 0–1).
- Training Mode:
- Chooses action: Random with probability ε, else
argmax(Q[state, :]). - Applies action:
mod_index = clip(mod_index + action, 0, 1). - Computes reward:
-|V_grid - max(|V_inverter|)|, with V_grid = 230 * sqrt(2). - Updates Q-table:
Q[state, action] += α * (reward + γ * max(Q[next_state, :]) - Q[state, action]).
- Chooses action: Random with probability ε, else
- Apply Mode: Uses trained Q-table to select actions without updates.
- Simulation:
- Runs for 100–10,000 steps.
- Tracks cumulative rewards and average Q-values.
- Restores original modulation index after training.
- Output: Stores rewards and Q-values for plotting and CSV export.
- Fixed Source:
- Model: Constant voltage output.
- Equation: V = user_defined (default 400V, range 100–800V).
- PV Panel:
- Model: Simplified I-V curve adjusted for irradiance (G) and temperature (T).
- Parameters: V_oc_STC = 500V, I_sc_STC = 10A, T_STC = 25°C, G_STC = 1000 W/m², α = 0.0005/°C, β = -0.003/°C, k = 0.05.
- Equations:
- Short-circuit current:
I_sc = I_sc_STC * (G / G_STC) * (1 + α * (T - T_STC)). - Open-circuit voltage:
V_oc = V_oc_STC * (1 + β * (T - T_STC)). - Current:
I = I_sc * (1 - (V / V_oc)^2). - Power:
P = V * I. - Voltage update:
V_new = V + k * (P - V * I)(iterated 5 times).
- Short-circuit current:
- Constraints: V clipped to 100–800V.
- Battery:
- Model: Voltage varies with state of charge (SOC).
- Parameters: V_nom = 400V, C_nom = 100Ah, discharge_rate = 0.1C, SOC = 0.1–1.0.
- Equations:
- Voltage:
V = V_min + (V_max - V_min) * SOC, where V_min = 0.9 * V_nom, V_max = 1.1 * V_nom. - Discharge:
SOC -= (discharge_current * time_step / 3600) / C_nom, where discharge_current = discharge_rate * C_nom.
- Voltage:
- Constraints: V clipped to 100–800V, SOC to 0.1–1.0.
- Fuel Cell:
- Model: Voltage decreases with load current.
- Parameters: V_nom = 400V, I_max = 20A, efficiency = 0.6.
- Equations:
- Voltage drop:
V_drop = 0.05 * load_current. - Voltage:
V = V_nom * efficiency - V_drop.
- Voltage drop:
- Constraints: V clipped to 100–800V.
- Hybrid Source:
- Model: Weighted average of PV, Battery, and Fuel Cell voltages.
- Weights: PV = 0.5, Battery = 0.3, Fuel Cell = 0.2.
- Equation:
V = 0.5 * V_pv + 0.3 * V_battery + 0.2 * V_fuel_cell. - Constraints: V clipped to 100–800V.
- Single-Phase Topology:
- Equations:
- Voltage:
V = 230 * sqrt(2) * sin(2 * π * f * t). - Current:
I = (V_dc * mod_index / 230) * sqrt(2) * sin(2 * π * f * t).
- Voltage:
- Equations:
- Three-Phase Topology:
- Equations:
- Voltage (per phase i):
V_i = 230 * sqrt(2) * sin(2 * π * f * t + θ_i), where θ_i = [0, -2π/3, 2π/3]. - Current:
I_i = (V_dc * mod_index / 230) * sqrt(2) * sin(2 * π * f * t + θ_i).
- Voltage (per phase i):
- Equations:
- Multilevel Inverters:
- Topologies: NPC, Flying Capacitor, Cascaded H-Bridge, MMC, Reduced Switch Count, Hybrid CHB+NPC.
- Voltage Levels:
- NPC, Flying Capacitor, Reduced Switch Count: [-V_dc/2, -V_dc/4, 0, V_dc/4, V_dc/2].
- Cascaded H-Bridge: [-V_dc, -V_dc/2, 0, V_dc/2, V_dc].
- MMC: [-V_dc/2, -3V_dc/8, -V_dc/4, -V_dc/8, 0, V_dc/8, V_dc/4, 3V_dc/8, V_dc/2].
- Hybrid CHB+NPC: [-3V_dc/4, -V_dc/2, -V_dc/4, 0, V_dc/4, V_dc/2, 3V_dc/4].
- PWM:
- Multicarrier: Compares reference
ref = mod_index * sin(2 * π * f * t)to thresholds[-1, 1] / (levels-1)to select output voltage. - Space Vector: Selects nearest level to
ref * 1.1 * V_dc/2.
- Multicarrier: Compares reference
- Equations:
- Voltage:
V_out = level_jwhereref > threshold_j. - Current:
I = V_out * (mod_index / 230).
- Voltage:
- Nominal Voltage:
- Equation:
V = 230 * sqrt(2) * sin(2 * π * f * t).
- Equation:
- Impedance:
- Parameters: R = 0.1Ω (1.0Ω weak), L = 0.001H (0.01H weak), I_load = 10A.
- Equation:
V_drop = R * I_load + L * 2 * π * f * I_load. - Output:
V = V_nominal - V_drop.
- Faults (duration 100ms):
- Sag:
V *= 0.8. - Swell:
V *= 1.2. - Harmonics:
V += 0.05 * 230 * sqrt(2) * (sin(10 * π * f * t) + sin(14 * π * f * t)). - Frequency Shift:
f += 2,V = 230 * sqrt(2) * sin(2 * π * (f+2) * t).
- Sag:
- Transformerless:
- DC Offset:
V += 0.01 * V_dc. - High-Pass Filter:
V[j] = α * (V[j] - V[j-1]) + V[j-1], α = 0.99. - Current:
I *= V_new / V_old(V_old = 1.0 if V_old < 1e-6).
- DC Offset:
- Transformer-Based:
- Efficiency:
V *= 0.95. - Phase Shift:
V(t) = V(t - 0.01)(interpolated). - Current:
I *= V_new / V_old(V_old = 1.0 if V_old < 1e-6).
- Efficiency:
- Perturb and Observe:
- Parameters: Step = 5V, V_oc = 500V, I_sc = 10A.
- Equations:
- Current:
I = I_sc * (1 - (V / V_oc)^2). - Power:
P = V * I. - Update: If
P > P_prev,V += direction * step; elsedirection *= -1,V += direction * step.
- Current:
- Constraints: V clipped to 100–800V.
- Incremental Conductance:
- Parameters: Step = 5V, V_oc = 500V, I_sc = 10A.
- Equations:
- Current:
I = I_sc * (1 - (V / V_oc)^2). - Power:
P = V * I. - Derivatives:
dV = V - V_prev,dI = I - I_prev. - Conductance:
inc_conductance = dI / dV,conductance = I / V(0 if V = 0). - Update:
- If
dV != 0:- If
inc_conductance > -conductance,V += step. - If
inc_conductance < -conductance,V -= step.
- If
- Else:
- If
dI > 0,V += step. - If
dI < 0,V -= step.
- If
- If
- Current:
- Constraints: V clipped to 100–800V.
- Constant Voltage:
- Equation:
V = 0.8 * V_oc = 0.8 * 500 = 400V. - Constraints: V clipped to 100–800V.
- Equation:
- Constant Current:
- Parameters: I_sc = 10A, V_oc = 500V.
- Equations:
- Target:
I_target = 0.9 * I_sc = 9A. - Current:
I = I_sc * (1 - (V / V_oc)^2). - Update:
V *= I_target / I(if I != 0).
- Target:
- Constraints: V clipped to 100–800V.
- Ripple Correlation Control:
- Parameters: Gain = 0.1, ripple_freq = 100Hz, V_oc = 500V, I_sc = 10A.
- Equations:
- Ripple:
V_ripple = 0.01 * V * sin(2 * π * 100 * t). - Voltage:
V_total = V + V_ripple. - Current:
I = I_sc * (1 - (V_total / V_oc)^2). - Power:
P = V_total * I. - Derivatives:
dV_dt = (V_total - V_prev) / dt,dP_dt = (P - P_prev) / dt. - Correlation:
correlation = dP_dt * dV_dt. - Update:
V_new = V - gain * correlation.
- Ripple:
- Constraints: V clipped to 100–800V.
- PI Control:
- Parameters: Kp_v = 0.5, Ki_v = 10, Kp_i = 0.2, Ki_i = 5.
- Equations:
- Errors:
error_v = V_ref - V,error_i = I_ref - I, where V_ref = 230 * sqrt(2) * sin(2 * π * f * t + φ), I_ref = 10 * sin(2 * π * f * t + φ). - Integral:
integral_error_v += error_v * time_step,integral_error_i += error_i * time_step. - Output:
V_out = V + Kp_v * error_v + Ki_v * integral_error_v,I_out = I + Kp_i * error_i + Ki_i * integral_error_i.
- Errors:
- PR Control:
- Parameters: Kp_v = 0.5, Kr_v = 50, Kp_i = 0.2, Kr_i = 20, ω_0 = 2 * π * f.
- Equations:
- Errors:
error_v = V_ref - V,error_i = I_ref - I. - Resonant:
resonant_v = Kr_v * sin(ω_0 * t + φ) * error_v,resonant_i = Kr_i * sin(ω_0 * t + φ) * error_i. - Output:
V_out = V + Kp_v * error_v + resonant_v,I_out = I + Kp_i * error_i + resonant_i.
- Errors:
- Sliding Mode:
- Parameters: λ_v = 100, λ_i = 50, K_v = 10, K_i = 5.
- Equations:
- Errors:
error_v = V_ref - V,error_i = I_ref - I. - Surfaces:
s_v = error_v + λ_v * (error_v - prev_error_v),s_i = error_i + λ_i * (error_i - prev_error_i). - Output:
V_out = V + K_v * sign(s_v),I_out = I + K_i * sign(s_i). - Update:
prev_error_v = error_v,prev_error_i = error_i.
- Errors:
- MPC:
- Parameters: R = 0.1Ω, L = 0.01H.
- Equations:
- Predictions:
V_pred = V + (time_step / L) * (V_ref - V - R * I),I_pred = I + (time_step / L) * (V_pred - V_ref). - Cost:
cost = (V_ref - V_pred)^2 + (I_ref - I_pred)^2. - Output: If
cost < 2,V_out = V_pred,I_out = I_pred; elseV_out = V,I_out = I.
- Predictions:
- Parameters:
- Error bins: 10, from -50V to 50V.
- Actions: [-0.1, -0.05, 0, 0.05, 0.1].
- α = 0.01–1, γ = 0–1, ε = 0–1.
- Equations:
- State:
state = digitize(error, bins) - 1, error = 230 * sqrt(2) - max(|V_inverter|). - Action: Random if
rand() < ε, elseargmax(Q[state, :]). - Reward:
R = -|error|. - Update:
Q[state, action] += α * (R + γ * max(Q[next_state, :]) - Q[state, action]).
- State:
- Parameters: k = 0.5, Kp = 2.0, Ki = 100.0, ω = 2 * π * f.
- Equations:
- Error:
v_error = V_grid - v. - SOGI:
v += time_step * (k * v_error * ω - q * ω^2),q += time_step * v. - Phase:
θ = arctan2(q, v)(if v != 0, else previous phase). - Phase Error:
phase_error = sin(θ - phase). - Adjustment:
ω_adjust = Kp * phase_error + Ki * integral_error,integral_error += phase_error * time_step. - Output:
phase += (ω + ω_adjust) * time_step,phase %= 2 * π.
- Error:
- Parameters: V_nom = 230 * sqrt(2), f_nom = 50Hz, V_min = 0.88 * V_nom, V_max = 1.1 * V_nom, f_min = f_nom - 1, f_max = f_nom + 1, active_freq_shift = 0.5Hz, active_q = 0.05.
- Passive Detection:
- Voltage:
V_peak = max(|V_grid|). Detect ifV_peak < V_minorV_peak > V_max. - Frequency:
freq = 1 / (2 * period), where period is time between zero crossings. Detect iffreq < f_minorfreq > f_max.
- Voltage:
- Active Detection:
- Frequency Shift (every 100ms):
freq += active_freq_shift * sign(freq - f_nom). - Reactive Power:
Q_inject = active_q * V_peak. Detect if|Q_inject - last_voltage| > 0.1 * V_nom.
- Frequency Shift (every 100ms):
- Input Processing: User inputs update simulation parameters via signals in
Main.py. - Waveform Pipeline:
InverterSimulation.generate_waveformschains DC source → MPPT → topology → PWM → control → design to produce waveforms. - Grid Feedback: Grid voltage from
GridSimulation.pyfeeds into PLL and islanding detection. - Data Management:
- Time-domain: Stored in
Zeitbereichssimulation.pyandMain.pyfor plotting/export. - Frequency-domain: Stored in
FrequenzbereichsUndKleinsignalanalyse.py. - Adaptive control: Stored in
AdaptiveKontrollstrategien.py.
- Time-domain: Stored in
- Reset: All components reset to initial states (e.g., V = 400V, phase = 0) for consistent restarts.